Detection of abnormalities in the superficial zone of cartilage repaired using a tissue engineered construct derived from synovial stem cells
1 Department of Orthopaedics, Osaka University Graduate School of Medicine, Suita, Osaka, Japan
2 McCaig Institute for Bone and Joint Health, Faculty of Medicine, University of Calgary, Calgary, Alberta, Canada
3 Department of Orthopaedics, Kansai Rosai Hospital, Amagasaki, Hyogo, Japan
4 Biomechanics Laboratory, Department of Mechanical Engineering, Kogakuin University, Hachioji, Tokyo, Japan
5 Biomechanics Laboratory, Faculty of System Design, Tokyo Metropolitan University, Hino, Tokyo, Japan
6 Center for Advanced Medical Engineering and Informatics, Osaka University, Suita, Osaka, Japan
7 Institute for Medical Science in Sports, Osaka Health Science University, Osaka, Japan
Abstract
The present study investigated the surface structure and mechanical properties of repair cartilage generated from a tissue engineered construct (TEC) derived from synovial mesenchymal stem cells at six months post-implantation compared to those of uninjured cartilage. TEC-mediated repair tissue was cartilaginous with Safranin O staining, and had comparable macro-scale compressive properties with uninjured cartilage. However, morphological assessments revealed that the superficial zone of TEC-mediated tissue was more fibrocartilage-like, in contrast to the middle or deep zones that were more hyaline cartilage-like with Safranin O staining. Histological scoring of the TEC-mediated tissue was significantly lower in the superficial zone than in the middle and deep zones. Scanning electron microscopy showed a thick tangential bundle of collagen fibres at the most superficial layer of uninjured cartilage, while no corresponding structure was detected at the surface of TEC-mediated tissue. Immunohistochemical analysis revealed that PRG4 was localised in the superficial area of uninjured cartilage, as well as the TEC-mediated tissue. Friction testing showed that the lubrication properties of the two tissues was similar, however, micro-indentation analysis revealed that the surface stiffness of the TEC-repair tissue was significantly lower than that of uninjured cartilage. Permeability testing indicated that the TEC-mediated tissue exhibited lower water retaining capacity than did uninjured cartilage, specifically at the superficial zone. Thus, TEC-mediated tissue exhibited compromised mechanical properties at the superficial zone, properties which need improvement in the future for maintenance of long term repair cartilage integrity.
Keyword
- Cartilage tissue engineering; animal model; image analysis; mechanical properties; mechanical test; microstructure